Overview

Catchment Bunyip River
Site Tanti Creek at Stones Crossing ME_ETN600
Date and Time Monday 11th January 2016 11:51am
Approved Approved

Notes

Physical Chemical Tests

Ammon-Nit mg/L NH3-N N mg/L NH4+ D.O. % D.O mg/L EC µS/cm FrP mg/L P Nitrate-Nit mg/L N pH pH Units rP mg/L P Air ° C Water ° C Turb FAU Turb NTU
Sample 0.02 100 6580 6 0.03 29 19.4 3
Weather overcast
Last rainfall More than a week ago
Flow estimate MEDIUM: flow is normal/typical average flow
Water Appearance Scummy
Stream depth 0 - 50cm
Stream width 2m - 5m
Hazards
Litter/Pollutants packets
Water clarity good but patches of creamy scum on edges of banks and around any reeds or objects in the water. In one spot about 70m downstream where a restriction in the creek has led to a build-up of the scum it looks like a water/oil emulsion

Diary photos

No diary entries recorded for this visit

Creative Commons CC BY
All content, files, data and images provided by the Waterwatch Data Portal and Gallery are subject to a Creative Commons Attribution License