Overview

Catchment Lake Victoria
Site Forge Creek, Jenners Rd waterhole - Site 3 EG_FOR050
Date and Time Friday 23rd November 2012 10:03am
Approved Approved

Notes

Physical Chemical Tests

EC µS/cm pH pH Units rP mg/L P Air ° C Water ° C Turb FTU Turb NTU
Sample 412 6.84 0.01 19.1 19 9
Weather cloudy
Last rainfall During the last week 7.3
Flow estimate POOLS: No continuous flow in channel and intermittent pools (in-stream habitats not connected)
Water Appearance Scummy,Oily
Stream depth 0 - 50cm
Stream width 2m - 5m
Hazards
Litter/Pollutants petrol/diesel
surface scum with some hydrocarbon film present

Diary photos

No diary entries recorded for this visit